{"id":2344,"date":"2023-11-07T16:27:01","date_gmt":"2023-11-07T06:27:01","guid":{"rendered":"https:\/\/pioneeriot.com\/?page_id=2344"},"modified":"2024-02-27T08:53:51","modified_gmt":"2024-02-26T22:53:51","slug":"nb-iot-ultrasonic-smart-water-meter","status":"publish","type":"page","link":"https:\/\/pioneeriot.com\/?page_id=2344","title":{"rendered":"NB IoT Ultrasonic Smart Water Meter"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;section&#8221; _builder_version=&#8221;4.23&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row column_structure=&#8221;3_5,2_5&#8243; _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;3_5&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>Pioneer NB IoT Ultrasonic Smart Water Meter<\/h1>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>Introducing the Pioneer Ultrasonic Water Meter Model: DN20+ and DN25+ \u2013 an essential tool for measuring cold potable water, designed to ensure a seamless supply for trade. This innovative water meter offers a range of impressive features and functions, making it a top choice for water measurement needs.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>The Pioneer Ultrasonic Water Meter Model: DN20+ is built to excel in various conditions. Some <span>notable attributes:<\/span><\/p>\n<ul>\n<li>Minimum flow rate (Q1): 0.01 m3\/h<\/li>\n<li>Transition flow rate (Q2): 0.016 m3\/h<\/li>\n<li>Maximum continuous flow rate (Q3): 4.0 m3\/h<\/li>\n<li>Overload flow rate (Q4): 5.0 m3\/h<\/li>\n<li>Flow rate ratio (Q3\/Q1): 400<\/li>\n<li>Maximum admissible temperature: 50\u00b0C<\/li>\n<li>Maximum admissible pressure: 1600 kPa<\/li>\n<li>Pressure loss class: \u0394p 40<\/li>\n<li>Accuracy class: 2<\/li>\n<li>Flow profile sensitivity class: U0\/D0 \u2013 suitable for various applications<\/li>\n<li>Electromagnetic class: E1 (residential, commercial, light industrial)<\/li>\n<li>Environmental class: B &amp; O (indoor and outdoor)<\/li>\n<li>Orientation: Suitable for all positions<\/li>\n<li>Flow Direction: Forward<\/li>\n<li>Power supply: Non-replaceable battery (3.0-3.6 V)<\/li>\n<\/ul>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;2_5&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/pioneeriot.com\/wp-content\/uploads\/2023\/11\/25mm-WM-right-open-1.png&#8221; title_text=&#8221;25mm WM right open 1&#8243; align=&#8221;center&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h3 style=\"text-align: center;\">NMI 14-3-47 Ultrasonic Water Meter<\/h3>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/pioneeriot.com\/wp-content\/uploads\/2023\/11\/IoT-water-meter-logos-scaled-1.png&#8221; title_text=&#8221;IoT water meter logos scaled&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; width=&#8221;100%&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;Features\/Functions&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<div class=\"group w-full text-token-text-primary border-b border-black\/10 gizmo:border-0 dark:border-gray-900\/50 gizmo:dark:border-0 bg-gray-50 gizmo:bg-transparent dark:bg-[#444654] gizmo:dark:bg-transparent\" data-testid=\"conversation-turn-3\">\n<div class=\"p-4 gizmo:py-2 justify-center text-base md:gap-6 md:py-6 m-auto\">\n<div class=\"flex flex-1 gap-4 text-base mx-auto md:gap-6 gizmo:gap-3 gizmo:md:px-5 gizmo:lg:px-1 gizmo:xl:px-5 md:max-w-2xl lg:max-w-[38rem] gizmo:md:max-w-3xl gizmo:lg:max-w-[40rem] gizmo:xl:max-w-[48rem] xl:max-w-3xl }\">\n<div class=\"relative flex w-[calc(100%-50px)] flex-col gizmo:w-full lg:w-[calc(100%-115px)] agent-turn\">\n<div class=\"flex-col gap-1 md:gap-3\">\n<div class=\"flex flex-grow flex-col max-w-full gap-3 gizmo:gap-0\">\n<div data-message-author-role=\"assistant\" data-message-id=\"2f420dbd-747a-4260-8329-9f9536a3090a\" class=\"min-h-[20px] flex flex-col items-start gap-3 whitespace-pre-wrap break-words overflow-x-auto\">\n<div class=\"markdown prose w-full break-words dark:prose-invert dark\">\n<p>The Pioneer Ultrasonic Water Meter Model: DN20+ 25+ is equipped with a cutting-edge design and various features, including:<\/p>\n<ul>\n<li>Connection type: Threaded end connections, standard R3\/4 G1<\/li>\n<li>Display: A digital, electronic, liquid crystal display with a maximum indication range of 9,999,999.9999 m3 in 0.0001 m3 increments<\/li>\n<li>Communications: Supports NB IoT and All Bandwidth<\/li>\n<li>Materials: Flow tube made of brass; Meter casing constructed from high-quality polymer material<\/li>\n<li>Meter length: Compact and space-saving at 154 mm<\/li>\n<li>Non-return device: Comes with check valves for added efficiency and control<\/li>\n<\/ul>\n<p>This Pioneer Ultrasonic Water Meter Model: DN20+ 25+ is a versatile and reliable solution for accurately measuring cold potable water, making it an ideal choice for trade-related water supply needs. Its robust features and functions ensure it can operate effectively in a variety of settings, while its user-friendly digital display and communication capabilities make it a standout choice in the industry. Plus, with its durable materials and non-return device, it&#8217;s designed to last and perform reliably for years to come.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"flex justify-between empty:hidden gizmo:justify-start gizmo:gap-3 lg:block gizmo:lg:flex\">\n<div class=\"text-gray-400 flex self-end lg:self-center justify-center gizmo:lg:justify-start mt-2 gizmo:mt-0 visible lg:gap-1 lg:absolute lg:top-0 lg:translate-x-full lg:right-0 lg:mt-0 lg:pl-2 gap-2 md:gap-3\">\n<div class=\"flex gap-1\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"relative\">\n<div class=\"absolute left-1\/2 top-0 mt-2 flex w-10\/12 -translate-x-1\/2 items-start justify-center sm:mt-[6px]\">\n<div data-projection-id=\"62\"><\/div>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;DN20 Flow Specifications&#8221; _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.24.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>The Pioneer Ultrasonic Water Meter Model: DN20+ is approved with the flowrates and technical characteristics as listed below<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.24.2&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<div>\n<table border=\"1\" style=\"margin-left: auto; margin-right: auto;\">\n<thead>\n<tr>\n<th>Meter size<\/th>\n<th style=\"text-align: center;\">DN20<\/th>\n<th style=\"text-align: center;\">DN20<\/th>\n<th style=\"text-align: center;\">DN20<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Minimum flowrate Q<sub>1<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\"><strong>0.01<\/strong><\/td>\n<td style=\"text-align: center;\">0.013<\/td>\n<td style=\"text-align: center;\">0.016<\/td>\n<\/tr>\n<tr>\n<td>Transitional flowrate Q<sub>2<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\"><strong>0.016<\/strong><\/td>\n<td style=\"text-align: center;\">0.02<\/td>\n<td style=\"text-align: center;\">0.0256<\/td>\n<\/tr>\n<tr>\n<td>Maximum continuous flowrate Q<sub>3<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\"><strong>4.0<\/strong><\/td>\n<td style=\"text-align: center;\">4.0<\/td>\n<td style=\"text-align: center;\">4.0<\/td>\n<\/tr>\n<tr>\n<td>Overload flowrate Q<sub>4<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\"><strong>5.0<\/strong><\/td>\n<td style=\"text-align: center;\">5.0<\/td>\n<td style=\"text-align: center;\">5.0<\/td>\n<\/tr>\n<tr>\n<td>Ratio Q<sub>3<\/sub>\/Q<sub>1<\/sub><\/td>\n<td style=\"text-align: center;\"><strong>400<\/strong><\/td>\n<td style=\"text-align: center;\">315<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<\/tr>\n<tr>\n<td>Meter Length (mm)<\/td>\n<td style=\"text-align: center;\"><strong>154<\/strong><\/td>\n<td style=\"text-align: center;\">154<\/td>\n<td style=\"text-align: center;\">154<\/td>\n<\/tr>\n<tr>\n<td>Maximum Admissible Pressure (kPa)<\/td>\n<td style=\"text-align: center;\"><strong>1600<\/strong> or 1400<\/td>\n<td style=\"text-align: center;\">1600 or 1400<\/td>\n<td style=\"text-align: center;\">1600 or 1400<\/td>\n<\/tr>\n<tr>\n<td>Pressure loss class<\/td>\n<td style=\"text-align: center;\"><strong>\u0394p 63<\/strong> or \u0394p 40<\/td>\n<td style=\"text-align: center;\">\u0394p 63 or \u0394p 40<\/td>\n<td style=\"text-align: center;\">\u0394p 63 or \u0394p 40<\/td>\n<\/tr>\n<tr>\n<td>Verification scale interval (m<sup>3<\/sup>)<\/td>\n<td style=\"text-align: center;\"><strong>0.0001<\/strong><\/td>\n<td style=\"text-align: center;\">0.0001<\/td>\n<td style=\"text-align: center;\">0.0001<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_heading title=&#8221;DN25 Flow Specifications&#8221; _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.23&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p>Pioneer Ultrasonic Water Meter Model: DN25+ flowrates and technical characteristics as listed below<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.24.2&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<div>\n<table border=\"1\" style=\"margin-left: auto; margin-right: auto;\">\n<thead>\n<tr>\n<th>Meter size<\/th>\n<th style=\"text-align: center;\">DN25<\/th>\n<th style=\"text-align: center;\">DN25<\/th>\n<th style=\"text-align: center;\">DN25<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Minimum flowrate Q<sub>1<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\">0.01575<\/td>\n<td style=\"text-align: center;\">0.02<\/td>\n<td style=\"text-align: center;\">0.0252<\/td>\n<\/tr>\n<tr>\n<td>Transitional flowrate Q<sub>2<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\">0.0252<\/td>\n<td style=\"text-align: center;\">0.032<\/td>\n<td style=\"text-align: center;\">0.04<\/td>\n<\/tr>\n<tr>\n<td>Maximum continuous flowrate Q<sub>3<\/sub> (m<sup>3<\/sup>\/h)<\/td>\n<td style=\"text-align: center;\">6.3<\/td>\n<td style=\"text-align: center;\">6.3<\/td>\n<td style=\"text-align: center;\">6.3<\/td>\n<\/tr>\n<tr>\n<td>Overload flowrate Q<sub>4<\/sub> (m3\/h)<\/td>\n<td style=\"text-align: center;\">7.875<\/td>\n<td style=\"text-align: center;\">7.875<\/td>\n<td style=\"text-align: center;\">7.875<\/td>\n<\/tr>\n<tr>\n<td>Ratio Q<sub>3<\/sub>\/Q<sub>1<\/sub><\/td>\n<td style=\"text-align: center;\">400<\/td>\n<td style=\"text-align: center;\">315<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<\/tr>\n<tr>\n<td>Meter Length (mm)<\/td>\n<td style=\"text-align: center;\">178<\/td>\n<td style=\"text-align: center;\">178<\/td>\n<td style=\"text-align: center;\">178<\/td>\n<\/tr>\n<tr>\n<td>Maximum Admissible Pressure (kPa)<\/td>\n<td style=\"text-align: center;\">1600 or 1400<\/td>\n<td style=\"text-align: center;\">1600 or 1400<\/td>\n<td style=\"text-align: center;\">1600 or 1400<\/td>\n<\/tr>\n<tr>\n<td>Pressure loss class<\/td>\n<td style=\"text-align: center;\">\u0394p 63 or \u0394p 40<\/td>\n<td style=\"text-align: center;\">\u0394p 63 or \u0394p 40<\/td>\n<td style=\"text-align: center;\">\u0394p 63 or \u0394p 40<\/td>\n<\/tr>\n<tr>\n<td>Verification scale interval (m<sup>3<\/sup>)<\/td>\n<td style=\"text-align: center;\">0.0001<\/td>\n<td style=\"text-align: center;\">0.0001<\/td>\n<td style=\"text-align: center;\">0.0001<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pioneer NB IoT Ultrasonic Smart Water MeterIntroducing the Pioneer Ultrasonic Water Meter Model: DN20+ and DN25+ \u2013 an essential tool for measuring cold potable water, designed to ensure a seamless supply for trade. This innovative water meter offers a range of impressive features and functions, making it a top choice for water measurement needs.The Pioneer [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"_links":{"self":[{"href":"https:\/\/pioneeriot.com\/index.php?rest_route=\/wp\/v2\/pages\/2344"}],"collection":[{"href":"https:\/\/pioneeriot.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pioneeriot.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pioneeriot.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pioneeriot.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2344"}],"version-history":[{"count":7,"href":"https:\/\/pioneeriot.com\/index.php?rest_route=\/wp\/v2\/pages\/2344\/revisions"}],"predecessor-version":[{"id":2408,"href":"https:\/\/pioneeriot.com\/index.php?rest_route=\/wp\/v2\/pages\/2344\/revisions\/2408"}],"wp:attachment":[{"href":"https:\/\/pioneeriot.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2344"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}